►►7.1. HANDLING:
en
See Fig. 7
The heater can be easily handled by the wheels
it
and handles. To handle the heater better:
de
►7.1.1. Release the handles from their closed
position (pull the locking pin outwards).
es
►7.1.2. Lock the handles in a handling position.
►7.1.3. Move the heater by lifting the handles and
fr
making it slide on its wheels.
►7.1.4. Put the handles back into their closed
nl
position.
pt
►►7.2. TRANSPORT:
da
See Fig. 8
It is possible to lift and move the heater from the
fi
specific anchoring points.
no
sv
►►8. DISPLAY ERRORS
See B Fig. 3
pl
ERROR
ru
F0
1. The "ON/OFF" switch is turned "ON"
cs
(|) when the heater is plugged in
hu
sl
F1
1. No fuel
2. Fuel is contaminated
tr
hr
3. Photocell is dirty or damaged
lt
4. Fuel filter is dirty
5. Ignition error
lv
et
F2
1. Interrupted cable
2. Sensor is damaged
ro
F3
sk
1. Internal heater overheating
bg
2. Antitilting sensor intervent
uk
bs
F4
1. Incorrect voltage
el
FF
1. No fuel
zh
2. Dirty fuel filter
3. Dirty or defective photocell
4. Dirty or defective nozzle
5. Anti-tilting sensor trip
[ ]
1. Thermostat connected
2. Switching from cable to battery pow-
er supply
CAUSE
OPERATION ERROR
PHOTOCELL ERROR
TEMPERATURE CONTROL SENSOR ERROR
THERMOSTAT ERROR
INCORRECT VOLTAGE
NO SWITCH-ON AFTER THREE ATTEMPTS
HEATER IN STAND-BY
►►7.3. STORAGE:
IN ORDER TO KEEP THE HEATER IN THE BEST
POSSIBLE CONDITIONS, WE RECOMMEND
FOLLOWING THE PROCEDURE BELOW:
►7.3.1. Empty the fuel from the tank by removing
the discharge plug at the bottom of the tank.
Dispose of the fuel appropriately and in line with
current standards.
►7.3.2. If you notice any residue, pour clean fuel
into the tank and rinse again.
►7.3.3. Close the drain plug and the tank plug.
►7.3.4. In order to keep the heater in the best
conditions possible, we recommend placing
it in a dry place away from potential external
damage.
SOLUTION
1. After disconnecting the heater, see that the
switch is in the "OFF" (0) position, plug the
heater in and turn the switch "ON" (|)
1. Turn the switch "OFF" (0), refill the fuel tank
2. Turn the switch "OFF" (0) empty and refill
the fuel tank. Clean the filter using clean
fuel, do not damage the filter (SEE PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
1. Contact the technical service center
2. Contact the technical service center
1. Turn the heater off, wait until it is cooled
down
2. Place the heater on a level and stable
surface
1. Check voltage of your electric supply system
1. Contact the technical service center
2. Contact the technical service center
3. Contact the technical service center
4. Contact the technical service center
5. Contact the technical service center
1. Thermostat temperature set below the room
temperature
2. Automatic re-ignition