5. Once all parameters are set, to exit and to go back to the programming menu, press
for a short time the key
To exit and to go back to the normal operation (automatic, manual) press for a long
time the key
or wait for the time-out expiration (30 seconds about).
If a timing is active, the display shows the symbol
To interrupt a timing, access again the menu and set the value 00.
With the ADV menu it's possible to modify the
following operation parameters:
- operating mode (heating or cooling)
- regulation type (on-off or proportional)
- parameters relative to regulation type
- antifreeze temperature
- password for key lock
- system operation hours.
To access the menu ADV:
1. From the normal operation display, press for a long time the key
symbol
starts flashing on field
2. Press for a short time the key
key
to access the parameters modification.
3. At this point the first parameter of the menu starts flashing:
press the keys
to move to the next parameter.
To exit the parameters modification press the key
.
.
until the symbol
and
to modify the parameter and the key
- 16 -
CHRONOS Programmable Thermostat User Manual
.
until the
starts flashing and press the
to confirm and
.