DTCXSL01EN - v1 - ENGLISH
2 - TECHNICAL FEATURES
Power supply
Power consumption
Operating temperature
Measurements:
Maximum length of cables
3 - COMPATIBILITY
The SMART selector is only compatible with the manusa
VISIO operator.
4 - SELECTION OF THE DOOR OPERATING MODE
12 V DC
You can choose the door operating mode by pressing
6 mA
the left or right selection buttons. Area 6 of the
0 to 50ºC
selector will blink with the icon of the mode selected.
Use the central confirmation button to accept the
100x75x26 mm
mode.
10m
OPEN MODE
The door will open and stay in that position. In this
mode, the leaves can be moved manually.
CLOSE MODE
In doors without auto lock, this operating mode
closes the door and releases the leaves. In
doors with auto lock, the leaves will close and
will become blocked.
Note: if the interior detector or pushbutton is
activated during the closing cycle, the leaves will
reopen and will then reattempt a new closing cycle
until the leaves are fully closed.
*Whenever required, the Technical Service may configure the
door to delay the activation of the lock, to let the user reach the
door and exit the premises before the leaves become blocked.
AUTOMATIC MODE
The door will complete a full open & closing cycle
each time a detector (interior or exterior) is activated.
EXIT ONLY MODE
The door will only open when the interior detector or
push button is activated.
*Note: if the door has an automatic lock, the
Leaves will remain blocked until they are in
closed position.
7
SMART SELECTOR WITH LCD - USER MANUAL