_______________________________________________________________________________
I. Features
a.
Power Quality Analysis for Single and Balanced Three Phase System.
b.
Harmonic Analysis of Voltage and Current (1 to 50
c. True RMS measurement of V with 0.5% basic accuracy.
d.
True RMS measurement of A with 1% of range basic accuracy
e.
Graphic Waveform of Voltage and Current
f. Graphic Phasor Diagram
g. Transient Detection and Logging of Swell, Dip, and Outage.
h.
Fast peak function (39 s for 50 Hz, 33 s for 60Hz).
i. Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power
j. Power factor (PF), phase angle (Φ), and energy (WH, KWH).
k. Measurement of balanced 3Φ Power Quality.
l. Programmable VT ratio from 1 to 3000
m. Hold functions.
n. Auto power off function in 15 minutes.
©Copyright Abacanto Digital SA.
Manual de usuario AD6810
AD Instruments
th
order).
84