4.
INSTALLATION
Before filling the solar circuit, it is advisable to provide a pressure reducer if the mains pressure exceeds 6
bar.
4.6
POSITIONING
When selecting the place of installation of the appliance, follow the safety instructions below:
- Place the appliance in places where it is possible to prevent access by children as a potential source of danger for
their safety.
- Make sure that the fastening is carried out according to what is illustrated in this manual.
- Make sure that there are no high temperature parts that can come into contact with people, animals or objects that
are sensitive to high temperatures: if not, provide for safety fences
The appliance must be lifted using the appropriate handles (FIG_04-2) in order to avoid compromising the
seal of the black seal that seals the cup and the tray.
It must be positioned in a place where the breakage of any of the elements provided can not cause any
damage to people or things.
4.7
ORIENTATION
Position the appliance so that the capturing surface is exposed to the South or in any case in the east-south-west
quadrant (FIG_04-3) avoiding shading areas (FIG_04-4). The north-facing exposure affects the performance of the
panels (FIG_04-5).
4.8
GRADE OF INCLINATION
When choosing the inclination (when not required due to a sloped roof installation) take into consideration: the
variation of the inclination of the sun's rays during the year and the location of installation.
The holes on the solar panel frame (FIG_04-6) allow you to reach three different inclinations depending on the location
where the appliance will be installed:
- A-A: 11 ° tilting
- B-B: 28 ° tilting
- C-C: 36 ° tilting
For installations on flat surfaces, respect the following grade of inclinations:
LATITUDE
CITY
0 ° .. 43 °
43 °.. 54 °
54 °.. 65 °
For installations on tilting roofs, if it is not possible to recreate the installation similar to the flat surface (FIG_04-7),
always use the inclination A-A
When installing more than one appliance on a flat surface, minimum distances must be respected to avoid shaded
areas (FIG. 04-8).
LATITUDE
0 °.. 43 °
43 °.. 54 °
54 °.. 65 °
Rome - Napoli - Catania
Madrid - Athens - Casablanca
Bolzano - Milan - Bologna - Florence
Paris - Amsterdam - London - Wuerzburg
Stockholm
CITY
Rome - Napoli - Catania
Madrid - Athens - Casablanca
Bolzano - Milan - Bologna - Florence
Paris - Amsterdam - London - Wuerzburg
Stockholm
Pag.7 / 9
ENGLISH
GRADE
OF
INCLINATION
A-A: tilting 11 °
B-B: tilting 28 °
C-C: tilting 36 °
D. min
2 m
3 m
4 m

Publicidad