Descargar Imprimir esta página

Air Supply; Air Connections; Hydraulic Connections; Torque Specifications - Enerpac 10,000 PSI TURBO II Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
DANGER: Do not handle pressurized hoses. Escaping
oil under pressure can penetrate the skin, causing serious
injury. If oil is injected under the skin, see a doctor
immediately.
WARNING: Only use hydraulic cylinders in a coupled
system. Never use a cylinder with unconnected couplers.
If the cylinder becomes extremely overloaded, components
can fail catastrophically causing severe personal injury.
WARNING: BE SURE SETUP IS STABLE BEFORE
LIFTING LOAD. Cylinders should be placed on a flat
surface that can support the load. Where applicable, use
a cylinder base for added stability. Do not weld or otherwise modify
the cylinder to attach a base or other support.
Avoid situations where loads are not directly centered on
the
cylinder
plunger.
considerable strain on cylinders and plungers. In addition,
the load may slip or fall, causing potentially dangerous results.
Distribute the load evenly across the entire saddle surface.
Always use a saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must only be serviced
by a qualified hydraulic technician. For repair service,
contact the Authorized ENERPAC Service Center in your
area. To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or damaged parts
by genuine ENERPAC parts. Standard grade parts will
break causing personal injury and property damage.
ENERPAC parts are designed to fit properly and withstand high
loads.
3.0 DESCRIPTION
The 10,000 psi TURBO II Air Pumps have an operating pressure
of 10,000 psi at 85 psi inlet pressure. They are suited for plant
maintenance, fabrication, production, bolting, vehicle repair, and
any task that requires hydraulic pressure from air input.
4.0 SPECIFICATIONS
See table below.
SPECIFICATION TABLES
Model
Weight-add 1 lb.
No.
(.5 kg) for bracket
PATG1102N
18 lbs. [8,2 Kg]
PATG1105N
22 lbs. [10,0 Kg]
PAMG1402N
24 lbs. [10,9 Kg]
PAMG1405N
26 lbs. [11,8 Kg]
PARG1102N
22 lbs. [10,0 Kg]
PARG1105N
26 lbs. [11,8 Kg]
Model
Hydraulic
Hydraulic
Type
Air Ratio
Output Ports
PATG,
100:1
.375-18 NPTF
PAMG
PARG
100:1
.375-18 NPTF
Off-center
loads
produce
Reservoir
Series
2
5
Oil Flow
Oil Flow
@ 100 psi
@ 10,000 psi
(6.9 bar)
(700 bar)
60 cu.in/min.
10 cu.in/min.
(1.0 liters/min.)
(0.16 liters/min.)
45 cu.in/min.
5 cu.in/min
(0.74 liters/min.)
(0.08 liters/min.)
5.0 INSTALLATION

5.1 Air Supply

Pump operates with 25-125 psi [2,76 - 8,27 bar] air pressure. An
Enerpac RFL-102 (regulator/filter/lubricator) should be installed
upstream from pump to provide clean, lubricated air and allow for
air pressure adjustment.

5.2 Air Connections

See Illustration 1. Attach air supply to the
connection on the end of the pump. Use Teflon tape or similar
thread sealant. Torque to 20-25 ft. lbs [27-34 Nm].
PARG Models: See Illustrations 2 and 3. Attach air supply to either
1/4 NPT connections on top rear to handle or 1/4 NPT connection
on bottom of air pendant. Make sure the unused port is plugged.

5.3 Hydraulic Connections

TORQUE SPECIFICATIONS

Model Numbers
Hydraulic Ports
Ending In
N or NB
P or PB
1
/
NOTE: Use 1
wraps of Teflon tape the NPTF hose fittings only,
2
leaving the first complete thread free of tape to ensure that pieces
of tape do not break off and enter the system. Do not use tape
sealant on BSPP fittings.
PAMG, PARG and PATG Models: See illustration 4. Thread
hose(s) into outlet port(s) of pump (A). Hose fittings must be
torqued. See Torque Specifications Table. Pumps with treadles
(PATG) have one outlet port, and pumps with 4-way valves
(PAMG) have 2 outlet ports. Outlet port(s) are located on the
opposite end of pump from the air inlet connection.
NOTE: Valve block or treadle should be restrained when torquing
fittings. The reservoir base should not be bolted down or restrained
to compensate for the fitting installation torque.
Reservoir
Useable Oil
Capacity
Horizontal
Mount
150 cu.in
127 cu.in
(2.5 liters)
(2.1 liters)
255 cu.in
230 cu.in
(4.2 liters)
(3.8 liters)
Air Pressure
Range
25-125 psi
( 1,7-8,6 bar)
25-125 psi
( 1,7-8,6 bar)
2
1
/
4
Torque Fittings To
65 – 75 ft-lbs.
3
/
NPTF
8
(88–102 Nm)
14 – 18 ft-lbs.
1
/
BSPP
4
(19 – 24 Nm)
Usable Oil
Vertical
Mount
70 cu.in
(1.2 liters)
180 cu.in
(3.0 liters)
Air
Operating
Consumption @
Noise
100 psi (6.9 bar)
Level (dBA)
12 SCFM
76
(0.34 cu.m/min)
12 SCFM
76
(0.34 cu.m/min)
NPT swivel

Hide quick links:

Publicidad

loading