Electrical installation
Power supply
Max. rated power
Circuit breaker
RCCB
DANGER
Risk of fatal electric shock
> Disconnect electrical components from the power supply
before the installation.
> Check that all components are de-energised.
> Prevent the power supply from being switched on
accidentally.
39
Installing the power supply for the SensoWash
shower toilet (optional)
> Install the power supply line according to the
technical instructions for the SensoWash
> Connect the power supply only when the shower
toilet is installed.
40
Pre-installation/planning
> Plan a position for the concealed box:
• within 1700 mm (diagram A)
• outside the protection zones 0 – 2 (diagram B)
> Install a permanent power supply line there:
• Install a separate circuit breaker and residual-
current circuit breaker (RCCB) upstream
• Connect all pole disconnector mains switches
upstream located outside the protection zones
0 – 2 (diagram B)
–
45
49
Mounting the installation set
> Position the concealed box at the designated
point.
–
59
62
Connecting the toilet frame
> Connect the supply line to the transformer.
100-240 V, 50-60 Hz
10 W
I
= 16 A
N
I
≤ 30 mA
ΔN
A
®
.
®
Safety areas in accordance with DIN VDE 0100-701
B
0
6 0
* or the height of the highest shower head
/ water outlet that is permanently installed,
depending on which is higher
0-1700
0
6 0
0
1
2
0
70300110_Toilet frame_integrated hygienic flush
7