1) INSTALLATION INSTRUCTIONS
2) P1000 XL CPC Flush valve ND20 - G3/4" EN 12541 compliant
3) PRECAUTIONS FOR USE (The product guarantee depends on the respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully drain
the pipes which can damage the mechanisms or water passages (PRESTO® heads that can be dismantled from front).
Recommended operating pressure according to NF EN 816: 1 to 5 bars.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
4) - P1000 XL Flush tapware Class II
- CPC kit for partition of 1.5 to 20 cm
- CPC kit for partition of 20 to 30 cm
For partition > than 30 cm: contact us
(Note: The flush valves must be equipped with an individual shut-off valve)
Technical data:
- Connection male thread G3/4"
- 1/4 turn stop valve
- Automatic flow regulator.
- Adjustable supply volume: 6 to 9l. (Supplied set to 6l)
- CP Control with trigger with 0.75m of flexible tube Ø4
- Outlet connector for 28x1.5Ø PVC tube
5) Shut-off valve
6) Flush tube height 500mm minimum
7) In order to benefit from the acoustic grading of P1000XL, never use the shut-off valve for flow regulation. It
must be kept open
8) Flush tube : not supplied
9) Installation
10) Bleed the installation before installing the valve
11) Connect on inlet arrow
12) Tube green or black – Ø4 Lg: 0.75m
13) Green or black tube connection
14) Tube white – Ø4 Lg: 0.75m
15) Connect on outlet arrow
16) 1- Install the green or black tube as shown on the diagram; 2- Install the white tube
16a) ! Max. length of each tube 3 meters
17) Installation (See instructions for the cross-partition assembly)
18) Thickness of the wall (E)
19) 8mm distance adjustment of the cylinder
20) Adjusting the flow rate (P min.: 1.2 bars); (P max.: 4 bars)
21) Volume (litres)
22) Number of turns
23) Volume
24) Flow rate (l/s)
25) Flow rate diagram
26) Pressure (bar)
27) In the event of an anomaly, remove the cartridge and rinse in clean water
28) Dismantling the valve
29) Spare parts for P1000 XL Class II - Cartridge - :
30) P1000 XL TC trigger :
31) Replacing the cartridge
32) Cartridge + seals :
33) Foolproof location of the cartridge in the body
34) For the adjustment of the volume see chapter "Adjustment of the flow rate"
35) Foolproof location of the seal in the cartridge
36) This document is not contractual; we reserve the right to modify the characteristics of our products without notice.
37) PATENTED and REGISTERED MODELS
- Hydraulic trigger P1000 XL TC – :