Descargar Imprimir esta página

CORBERO CPGS423X Manual De Usuario página 39

Publicidad

Idiomas disponibles

Idiomas disponibles

Gas adjustment
6mm
1
Change the injector of the burners.
2
Adjustment of minimum level of the flame.
3mm
Take precautions on the operations and adjustments to be carried out when
converting from one gas to another.
All work must be carried out by a qualified technician.
Before you begin, turn off the gas and electricity supply to the appliance.
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and
replace it with the stipulated injector for new gas supply.
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly
tighten the injector in place.
Injector
Control handle
Tap
Sealing ring
Do not dismantle the tap shafe:
in the event of a malfunction,
change the whole tap.
Before placing the burners back
on the top place, make sure that
the injector is not blocked.
A full operational test and a test
for possible leakages must be
carried out after gas conversion,
(such as soap water or gas
detector)
Turn the taps down to minimum.
Remove the knob from the tap and place a small bladed
screwdriver in the centre of the Adjustment screw.
The correct adjustment is obtained when the flame has a
length of about 3-4 mm.
- For butane/ propane gas, the adjusting screw must.
- be tightly screwed in.
- Refit the control knob.
Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does then remove
the control knob and make further adjustments to the gas
flow, testing it again once the adjustment has been made.
Repeat this process for each one of the gas taps.
After completing conversion,
a qualified technician or installer
has to mark "V" on the right gas
category to match with the
setting in rating plate.
Remove the previous
setting "V" mark.
18

Publicidad

loading

Este manual también es adecuado para:

Cpcgm5f5021nCpcgm4f4121nCpcgm4f4122wCpcgm3f3122nCpcgm3f3122w