*Sump Pump
*Table Saw (10")
Television
Toaster
Weed Trimmer
* Allow 3 times the listed watts for starting these
devices.
Transporting/Tipping of the Unit
Do not operate, store or transport the unit at
an angle greater than 15 degrees.
Starting Pull Start Engines
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. See
Figure
3-2. Open the fuel shut-off
valve (A).
ON
OFF
Figure 3-2.Fuel Shut-off Valve
4. See
Figure
2-2. Turn engine RUN/STOP/
START switch to RUN/ON (manual start
only).
5. See
Figure
3-3. Slide engine choke (C) to
Full Choke position (left).
14
800 to 1050
1750 to 2000
200 to 500
1000 to 1650
WARNING
CAUTION
A
000208
500
6. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
7. When engine starts, move choke knob to
1/2-choke position until engine runs
smoothly, then fully into RUN position. If
engine falters, move choke back to 1/2-
choke position until engine runs smoothly,
then to RUN position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload the
generator. Also, do not overload individual
panel receptacles. These outlets are pro-
tected against overload with push-to-reset-
type circuit breakers. If amperage rating of
(000183)
any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
Limits
Starting Electric Start Engines
(000136)
(Push Start)
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. See
valve.
4. Press START/STOP button and wait for
one (1) second to prime the starter. The
button will blink green when ready.
5. Press the START/STOP button to start the
engine. The starter will attempt to start the
engine. Once started, the button will
remain illuminated for 20 seconds.
NOTE: If no start is achieved the START/
STOP button will blink red for 20 seconds.
Additional attempts to start the engine may be
tried after blinking stops.
C
Figure 3-3.Choke Position
carefully.
CAUTION
3-2. Open the fuel shut-off
Figure
Owner's Manual for Portable Generator
000209
Know Generator
(000136)