Descargar Imprimir esta página

Elite MC5 Manual De Usuario página 30

Ocultar thumbs Ver también para MC5:

Publicidad

Idiomas disponibles

Idiomas disponibles

M C
5
Keep Working
7.1 Wiring instruction:
J1 Terminal
Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is live wire, N is Neutral wire, and PE is groun-
ding wire.
J2 Terminal
Connect LAMP to caution light; voltage: AC220V/50HZ; AC110V/60HZ.
Connect the motor wire MOTL2 to the REV motor wire, connect MOTL1 to the FWD motor
wire, and connect MOTCOM to the motor common wire.
J3 Terminal
Connect CAP to the capacitor wire.
J4 Terminal
(For the convenience of wiring, this terminal is accompanied with failure diagnosis light)
OPEN: Gate open control button (N.O.)
CLOSE: Gate close control button (N.O.)
START: Open/Stop/Close/Stop loop control button (N.O.)
DET: Loop detector (sensor coil) connector (N.O.)
In the closing process, once vehicles are detected by the loop detector, the gate will open immediately; when the vehicle
passes, the gate will close automatically. When the gate is in a halted state, it will keep this state when vehicles are detected;
after the vehicle passes, the
gate will close automatically.
In the above loop detector function, users can make the gate close automatically some seconds later after the vehicle passes.
Change the No.4 key of the dip switch on circuit board,and the gate will close automatically some seconds later after the
vehicle passes.
STOP:Stop control button (N.O.)
PHOTO: Photocell input; NC or NO will be memorized while Travel Learning(4.3.6).
COM: Common terminal
12Vdc:Power supply for fittings: +12VDC ( Electric current ≤100mA)
J5 Terminal
(For the convenience of wiring, this terminal is accompanied with failure diagnosis light)
LSC: Close limit switch
COM: Limit switch and other input signal common terminal
LSO: Open limit switch
KEEP WORKiNG
08

Publicidad

loading