Descargar Imprimir esta página

Elite MC5 Manual De Usuario página 32

Ocultar thumbs Ver también para MC5:

Publicidad

Idiomas disponibles

Idiomas disponibles

M C
5
Keep Working
3. SBS MODE: OFF—Pedestrian mode; ON—No pedestrian mode.
4. MOT.DIRECTION: OFF—Left installation; ON---Right installation.
7.7 Infrared connection
Note: The infrared connection NC or NO will be memorized while Travel Learning.
Infrared photocell function: In the closing process, when infrared ray of the photocell is covered by people or objects during
its detection range, the gate will open immediately for security protection.
The distance between photocell receiver and photocell emitter should be more than 2 meters, otherwise will affect the induc-
tion of the photocell.
The following figure shows the NO infrared connection. If you want to connect to an NC infrared photo, just change to NC
port. Then please learn travel again to Memory the infrared NC connection.
Figura 2.
7.8 Remote control operation
Three button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by three buttons separately on the
remote control.
Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one button circularly on the
remote control.
KEEP WORKiNG
10

Publicidad

loading