TROUBLESHOOTING
The following table gives problems and actions that you can perform if your machine does not operate
correctly.
WARNING: Switch the machine off and remove the battery prior to any troubleshooting.
60V Commercial Backpack Blower
Problems
Battery indicator LED
flashing
Red error LED flashing
The product does not start
The product stops during
usage.
Excessive vibrations/ noise.
BATTERY
Problems
Error LED lit
Possible Causes
Low battery voltage.
Temperature issue.
Debris in the battery
connectors.
Battery needs to be charged.
Other problems
The battery is not fully
inserted to the machine.
Potential electrical issue.
The air intake screen is
blocked
Possible Causes
The battery is discharged
Temperature issue.
Others
Corrective Action
Charge the battery.
Remove the battery.
Let the machine cool down or warm up.
Clean the battery connectors with
compressed air or a soft brush.
Charge the battery.
Contact Service Agent.
Remove & reinsert battery fully.
Contact Service Agent.
Remove the battery;
Open the air intake and clear the
unwanted materials away.
Corrective Action
Charge the battery and check the charger
for proper operation.If battery fails to
charge, contact your Service Agent.
Use the battery in surroundings where
temperatures are between -4°F to 113°F
(-20°C to 45°C) for discharge.
Contact your Service Agent.