Set Advanced Mode Parameters
NOTE!: If you select a QSC Loudspeaker, you will see that the limiter is LOCKED. QSC has given these loudspeakers specific limiter
settings tailored for that loudspeaker that should not be changed. If there is a limiter applied in these voicings, you will be able to see
the applied limiter on the graph. The limiter is also locked if the 70V or 100V mode is selected.
HOME > OUTPUTS > SPKR PROC > LIMITER > ADV
Step 2 — Set the ADV Mode Parameters
F1: A B C D
ADV
Array Correction
EN
HOME > OUTPUTS > SPKR PROC > ARRAY (ENTER)
NOTE!: You must have a QSC line array loaded in order to access the Array Correction parameters.
Step 1 — Set Splay Angle and Number of Boxes in the Array
F1: A B C D
AC
Save a Loudspeaker
When you Save a speaker profile, you are saving all of the Output settings currently active for the channel. The new profile you save does not need to
be Loaded, it is already active.
HOME > OUTPUTS > SPKR PROC > SAVE SPKR (ENTER)
Step 1 — Save Loudspeaker About
ABOUT
This function is provided to enable saving a
speaker to the database.
BEFORE saving a speaker, enter the desired
speaker tuning parameters (Gain, Crossover,
EQ, Delay, and Limiter). THEN save the
speaker to the database.
TD-000434-00-B
Output
A
RMSThr
PkThr
100.0V
155.0V
Output
A
Splay Angle: Total cumlative
angle of the array.
Array Length: Total number of
boxes in the array.
Angle
Boxes #
15.0
4
SPEAKERS
SAVE
NEXT
RMSThr: 3.0V to 100.0V
PkThr: 5.0V to 155.0V
PkAttk: 0.10 ms to 20.0 ms
PkRel: 1.00 ms to 1.0 s
RMSAttk: 0.05 s to 10.0 s
RMSRel: 1.0 s to 60.0 s
Thr = Threshold, Pk = Peak, Attk = Attack, Rel = Release
Angle:
0.0° to 90.0°
Boxes #:
0 to 24
This function is provided to enable saving a
speaker to the database.
BEFORE saving a speaker, enter the desired
speaker tuning parameters (Gain, Crossover,
EQ, Delay, and Limiter). THEN save the speaker
to the database.
23
Scroll to select (RMSThr, PkThr,
PkAttk, PkRel, RMSAttk, & RMSRel)
To edit, press
Turn to adjust parameter
To confirm, press
To exit, press
Scroll to select (Angle or Boxes#)
To edit, press
Turn to adjust parameter
To confirm, press
To exit, press
To continue, press
ENTER
ENTER
EXIT
ENTER
ENTER
EXIT