Descargar Imprimir esta página

Olimpia splendid LIMPIA HERO Instrucciones Para El Uso Y El Mantenimiento página 24

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
If calcium becomes difficult to remove with a paintbrush:
Fill the tank with the mix of 1 spoon of white vinegar and 1 spoon of water.
Let solution stand for 5 minutes.
With the vinegar inside the tank, clean all the internal surfaces with a soft cloth or a brush to help removing limescale.
Also check mist nozzle and mist tube in water tank. Clean as needed.
Rinse the Base thoroughly with water to remove scale and vinegar solution.
4.1 - END OF SEASON STORAGE
Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
Dry the humidifier completely before storing. DO NOT store with water inside the bowl or Water Tank.
Pack the unit in its original carton and store in a cool, dry location.
If you experience a problem do not attempt to open the motor housing yourself. doing so may void
your warranty and cause damage to the humidifier or personal injury.
5 - TROUBLESHOOTING GUIDE
PROBLEM
Water vapor and humidity are not
produced.
Air blows but water vapor is not
produced.
Humidity level is low.
The humidity has a bad smell.
White dust is forming on nearby
furniture.
Unit has stopped working.
Water is accumulating outside of
unit or area surrounding unit.
Water dripping when refilling.
Increased noise level.
Flashing light symbols.
EN - 8
• Power plug: Unplug and then try again.
• Power Failure: When the power is returned, try again.
• Tank Installation: Make sure the tank is correctly attached.
• The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
• Excessive Water: Remove a certain amount of water from the tank.
• Detergent residue and/or oil ingredients from cosmetics, etc may be in tank; wash out
tank and try again.
• The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
• If you use hard water, replace with softer water.
• The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
• The water in the unit is too cold: Replace with cool, but not cold water.
• Poor maintenance or dirty water: Clean the product thoroughly, and fill it with fresh
water.
• Hard water may deposit a certain of dust. Dust in the air also settles because of added
humidity in the room. Use distilled water if this becomes a nuisance.
• No or low water. Unplug unit and refill tank.
• Saturation of humidity. Lower mist control setting.
• Unit not level and water is accumulating. Unplug and place on level surface. Point
spray away from objects. Raise unit on a water-resistant level surface at least 60 cm
from the floor.
• Water remaining on bottom of tank. Wipe tank or tilt to drain before transporting.
• Unit must be placed on a flat, level, hard surface. Make sure it is NOT placed on a soft
or absorbent surface.
• Indicates low water. Unplug and refill tank.
SOLUTION

Publicidad

loading