Trouble
Foot switch fails to
switch on.
Foot switch hoses can-
not be disconnected
from the unit.
8
Technical Specifications
Voltage
Working pressure:
Connecting pressure, external:
Air consumption:
Lamp power consumption:
Cable length, approx.:
Ø Compressed air hose:
interior:
exterior:
Ø Size of pipe union for external extraction unit:
interior:
exterior:
Dimensions (W x H x D):
Blasting chamber volume:
Tank capacity, each:
Weight (empty), approx.:
This product contains a light source of energy efficiency
class:
Environmental conditions for safe operation:
Ambient conditions:
Installation height, max.:
Ambient temperature:
Relative humidity:
Voltage fluctuations in the mains power supply from the
nominal value, max.:
Contamination level:
Over-voltage category:
*) Between 5 – 30 °C [41 - 86 °F], the unit can be operated at a relative humidity of up to 80 %� At temperatures be-
tween 31 - 40 °C [87�8 - 104 °F], the humidity must decrease proportionally in order to ensure operational readi-
ness (e�g�, at 35 °C [95 °F] = 65 % humidity; at 40 °C [104 °F] = 50 % humidity)� The unit may not be operated at
temperatures above 40 °C [104 °F]�
Possible cause
• No pressure at the compressed air
connection�
• Pneumatic hoses are kinked�
• Push-in connection is not released
(Fig� 2)�
• Inspect the compressed air lines and / or the com-
pressor�
• Reposition the hoses�
• Press the push-in connection ring on the hose side
firmly while pulling on the hoses.
220 - 240 V, 50 / 60 Hz
100 - 120 V, 50 / 60 Hz
1 - 6 bar [14�5 - 87 psi]
6 - 8 bar [87 - 116 psi]
[3�46 cfm at 87 pis]
35 mm [1�38 inch]
40 mm [1�57 inch]
395 x 285 x 460 mm
[15�6 x 11�2 x 18�1 inch]
2,000 m [6,500 ft] above sea level
Max� 80 % at 31 ºC [87�8 ºF],
decreasing linearly to 50 % at 40 ºC [104 ºF] *)
- 11 -
Corrective action
98 l/min at 6 bar
16 W
2 m
[78 inch]
4 mm [157 mil]
6 mm [236 mil]
20 l
[5�3 US gal]
1000 ml
[34 fl oz]
8�1 kg
[17�9 lbs]
F
Indoors
5 - 40 °C
[41 - 104 °F]
10 %
2
II
en