Alarm Recording; Settings For Alarm Recording - Sony HSR-X216 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Alarm Recording

The recorder automatically starts alarm recording
when it detects the specified trigger.
For the trigger, you can select the following alarm
signals independently or in combination:
1. External alarm input
2. Internal activity detection sensor (detection of a
change in luminance at the specified points on the
picture)
By activating pre-alarm recording, the recorder
continues recording the camera input, overwriting the
data for the specified duration. When the trigger is
detected, the recorder switches to regular alarm
recording. This enables you to check the image a
certain time before the trigger is actually detected.

Settings for Alarm Recording

For alarm recording, you may set the following
requirements, including the trigger.
Use the submenu 6. ALARM REC MODE SET of the
main menu 2. RECORD SET.
<ALARM REC MODE SET>
PICTURE QUALITY
AUDIO RECORDING
ALARM RECORDING
ALARM INTERLEAVE
PROGRAM GROUP
REC RATE :
25 FPS, DURATION : 5SEC
PRE-ALARM RECORDING
REC RATE :
FPS, DURATION :
***
c (12115 ALARMS CAN BE RECORDED)
ALARM TRIGGER
PICTURE QUALITY, AUDIO RECORDING
These items can be set the same as for normal
recording.
ALARM RECORDING
Select the mode to execute alarm recording:
ENABLED: To execute alarm recording regardless
of timer recording
AL-REC ON TIMER: To execute alarm recording
only while timer recording is in progress
AL-REC OFF TIMER: To execute alarm recording
only while timer recording is not in progress
ONY AL-REC ON TIMER: To execute alarm
recording during the period(s) set for timer
recording (timer recording itself is not performed)
OFF: No alarm recording
: HIGH
: OFF
: OFF
: ONLY
: OFF
:
***
***
: ALARM
ALARM INTERLEAVE
SW: To alternately record the image from the camera
in alarm status and those of all of the other
connected cameras.
Ex.:
Alarm camera t Normal camera A t Alarm camera t
Normal camera B t Alarm camera t Normal camera C, etc.
If multiple alarms are generated, the images of the
cameras in alarm status will be recorded in
sequence, and those of the cameras in normal
status will be inserted in between.
Ex.:
Alarm camera 1 t Normal camera A t Alarm camera 2 t
Normal camera B t Alarm camera 1 t Normal camera C t
Alarm camera 2 t Normal camera D, etc.
ONLY: To record the image from the camera in
alarm status only. If multiple alarms are
generated, the images of the cameras in alarm
status are recorded in sequence.
PROGRAM GROUP
When using the program-group function, select one of
P-1 to P-4. When the function is not used, select OFF.
For details on program recording, see "Choosing Cameras
for Recording" on page 29(GB).
REC RATE
When Program Recording is set to OFF, set the
recording rate in the same manner as for normal
recording.
DURATION
5 SEC–15 MIN: Set the duration of alarm recording
for all the active cameras in common.
CC: To make recording as long as the alarm signal is
ON (1 second at minimum).
INDIV.: Set the duration of alarm recording
individually for each camera with ALARM
DURATION SET of the submenu 7. ALARM
OPERATION SET.
PRE-ALARM RECORDING
To perform pre-alarm recording, set PRE-ALARM
RECORDING to ON, and select REC RATE and
DURATION for pre-alarm recording.
You may select from among 5S/10S/20S/40S/1M/2M/
3M/4M/5M/10M/15M.
35
(GB)

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Hsr-x209pHsr-x216p

Tabla de contenido