Installation
Connections
CAUTION
To prevent electric shock please consult
information in the "Electrical Requirements" section in
pages 3 and 5.
• The fast connections in the electrode holder and the
grounding clamp are inserted and turned one quarter of a
turn in a clockwise direction in the outlets found iin the
front panel to be secured.
Inverse Polarity (A)
• Connect the grounding clamp cable to the negative (-)
clamping screw in the welder.
• Connect grounding clamp cable (C) to the work piece.
• Connect the electrode holder cable to the positive (+)
clamping screw in the welder.
This configuration generates more heat in the electrode,
thus producing more heat with basic electrodes making it
ideal to weld thick pieces.
Direct Polarity (B)
• Connect the grounding clamp cable to the outlet (+).
• Connect the grounding clamp (C) to the work piece.
• Connect the electrode holder to the outlet (-).
This configuration generates more heat in the work piece
producing less warping of the piece and narrower cords
making it ideal to solder thin pieces.
• Connect the feeding cable (D) working voltage network
(127 V / 220 V).
WARNING
Before using the welder, it shall be
correctly grounded. Failure to comply with this warning
propitiates severe personal injuries.
The welder automatically detects the working
NOTE
voltage (No type of connection is necessary to be carried out).
Before using the welder shall be correctly
WARNING
grounded. Do not uninstall the ground cable. It could cause
severe personal injury.
C
Metal
work
bench
Set the adequate
electrode for the job
into the electrode holder
A
Inverse Polarity
C
B
Direct Polarity
D
7