Descargar Imprimir esta página

Grohe RED 30 328 Instrucciones De Instalación página 18

Ocultar thumbs Ver también para RED 30 328:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
Installation and commissioning
Flush pipes thoroughly before and after installation
(observe EN 806)!
Adjust bypass of filterhead according to local carbonate
hardness and connect filter cartridge.
The carbonate hardness can be tested by using the enclosed test
strip or the relevant water supplier can provide information on the
carbonate hardness.
Note: The volume of water in the storage heater will expand as
it is heated. The expansion water must drip out of the funnel of
the safety assembly.
This is a necessary and completely normal process.
Check all connections for leakage.
Retighten screw connections as necessary.
Control:
The control is set for operation with the S-size filter cartridge
(prod no.: 40 404 001) at the factory.
The control must be adjusted for operation with other filter
cartridges, see page 8 - 9.
Operation
Unlock the child lock to draw off boiling water, see A.
The button combination for filling pots with boiling water, see B.
Drawing off cold or hot water, see C.
Activating holiday mode, see D.
Service
Fault
Boiling water does not flow, handle
flashes magenta once
Boiling water does not flow, boiling
water in use
No display on the handle
Handle lights up magenta
permanently
The GROHE boiling water storage heater may only be repaired by
GROHE customer service.
Environment and recycling
For reasons of hygiene, it is not possible to recycle used filter
cartridges. Used filter cartridges can be disposed of hazard-free as
residual waste.
17
, see page 10.
Cause
• Filter not installed correctly
• Hoses kinked
• Water supply interrupted
• Software fault
• System fault
Note:
In order to prevent incorrect operation and for protection against
injury, we recommend affixing the sticker provided.
Maintenance and cleaning
CAUTION!
Risk of damage!
Always disconnect from the voltage supply before
carrying out maintenance work on the system. The plug-in
connector can then be disconnected.
If work is performed on mains power supply or in case of
any maintenance work, the GROHE Red boiling system
must be bled as otherwise blasts of steam could form as a
result.
• Draw off boiling water from the storage heater until just cold water
flows.
• Close the service valve, switch off the storage heater and
disconnect the mains plug.
• Open the lever on the fitting and as well as the rotary knob on the
safety assembly to depressurise the storage heater.
• Drain the storage heater (not required each time maintenance is
performed): Remove the cap or hose to the mixing valve and
drain the storage heater using the connecting hose to the safety
assembly.
• Inspect and clean all parts, replace as necessary and lubricate
with special fitting grease.
Remedial action
- Insert filter straight
½
(1
- 2 turns)
- Check hoses for kinks
- Open shut-off valves fully
- Switch off the storage heater, briefly disconnect from
the mains power supply and switch on again
- Contact GROHE customer service
The boiling water storage heater is an electrical device, to which
return and take-back obligations apply in many countries. GROHE
participates in such take-back systems in all relevant countries.
Devices with this marking do not belong in domestic
waste, but must be disposed of separately in
accordance with the relevant national regulations.

Publicidad

loading

Este manual también es adecuado para:

Red 30 083Red 30 079Red 30 325Red 30 327