INSTALLATION
Cleaning and maintenance
1.
Undo the locking screw on the underside of the appliance
using the provided Torx key.
Lift the appliance off the wall mounting bracket.
Make sure that the LED on the front of the appliance is off
before you open the appliance.
12.1 Cleaning
The interior of the appliance must be cleaned regularly to remove
dust deposits.
Open the appliance (see chapter "Installation / Opening the
appliance").
www.stiebel-eltron-usa.com
2.
Remove the dust from inside the appliance.
Fit the casing cover (see chapter "Installation / Fitting the
casing cover").
Hang the appliance on the wall mounting bracket (see chap-
ter "Installation / Installing the appliance").
12.2 Changing the HEPA filter
Note
A built-in filter must be replaced after 60,000 applica-
tions. The appliance can still be operated, but without
the effectiveness of a HEPA filter. After approx. 75,000 ap-
plications, the LED on the front of the appliance flashes
red. The appliance cannot be operated again until a new
filter is inserted.
The HEPA filter is available as a spare part, item no. 205638.
Open the appliance (see chapter "Installation / Opening the
appliance").
Replace the filter (see chapter "Installation / Installing the
HEPA filter").
Fit the casing cover (see chapter "Installation / Fitting the
casing cover").
Hang the appliance on the wall mounting bracket (see chap-
ter "Installation / Installing the appliance").
™
Ultronic
Plus & Premium Hand Dryers |