2. INSTALLATION DIAGRAM
Wall-mounted installation
Before installing the control unit in the intended location, check that the power cord can reach the
protected outlet and the cell cable can reach the intended location.
Disconnect the pool filtration pump before starting the installation. The system must be installed in
accordance with the standards currently in force in the country of installation. The Justsalt supply unit
must be fitted a minimum horizontal distance of 1,5 meter (or more, if required from local regulations)
from the pool.
Fix the box and the measuring chamber on the wall (optional). Caution, acid vapours can cause
irreversible damage to your device. Position the treatment product tanks accordingly.
The box must be placed vertically on a flat surface, with the cable downward. As this box is used to
evacuate heat (heat from internal components), it is important that the four sides of the box remain
unobstructed. Do not install the Justsalt behind a panel or in an enclosed space.
The cell must be installed horizontally with the electrical connections pointing downwards or upwards
to prevent the accumulation of water near them.
The electrical connections at cell-level must point downwards, to avoid any deposits of water or
humidity on them.
13
1 : Salt / temperature
2 : Cell
3 : Electronics unit
4 : Pool Ground
5 : Bracket
6 : pH probe (optional)
7 : Flowswitch
I
8
H
 
10
8 bis
4
SSS
12
ELEMENTS NOT SUPPLIED :
8 : Electrical power supply
8 bis : Electrical outlet
9 : Copper cable
10 : Filter
11 : Ground rod
12 : Heat pump
13 : Filtration pump
3
6
1
4
5
4
7
9
11
2
4