Disassembling, exchanging, and disposing of the ED05 pressure regulator
9
Disassembling, exchanging, and
disposing of the ED05 pressure
regulator
9.1
Disassembling the ED05 pressure regulator
Danger of burns caused by hot valve coils!
Touching the valve coils during operating may lead to burns.
Let the device cool off before disassembling it.
Do not touch the device during operation.
Disconnecting plugs when under voltage will damage the
device!
Large differences in potential occur when disconnecting
plugs under voltage, which could damage the device.
Make sure the relevant system component is not under
voltage before disassembling the device.
The following switch-off sequence must be observed in order to
disassemble the ED05 pressure regulator.
1. Stipulate a set point of 0 bar to exhaust the ED05 pressure
regulator and the outlet line at the outlet pressure
connection.
2. Switch off the 24 V DC supply voltage.
3. Remove the connected plugs.
4. Switch off the supply pressure and exhaust the supply line.
5. In case of direct connection, remove the pneumatic lines.
6. Loosen both of the M6 x 75 screws.
The ED05 pressure regulator may now be removed.