PROBLEM
Air leak from trigger
Air leak from exhaust
port
Air leak from cylinder
Slow & short travel
cycling
Excessive jams
Uneven clinch
Unclinched staple
PAGE 8 OF 24
TROUBLESHOOTING
WARNING! Stop using the stapler immediately if any of the following problems
occur. Serious personal injury could occur. Any repairs or replacements must
be done by a qualified person or authorized service center only.
CAUSE
O-ring on valve or on tube is
damaged.
O-Ring on valve or on tube is
damaged.
O-Ring on piston is damaged.
Piston rod port O-ring is damaged.
Check for loose screw or wear of
parts.
Slow & short travel cycle.
Teeth screws are loose.
Wrong staple size.
Insufficient lubrication.
Wrong staple size.
Teeth are loose or broken.
Slow & short travel cycle.
Replace O-ring.
Replace O-ring.
Replace O-ring.
Position eccentric pin and tighten screw.
Recheck for maximum efficiency.
• Adjust pin slightly upward if due to short travel.
• Adjust pin slightly downward if due to slow
cycling.
Adjust as noted above.
Tighten screws.
Check staples.
Clean and lubricate.
Check for proper leg length adjustment and
clincher size.
Check & replace teeth as needed.
Adjust as noted above.