Descargar Imprimir esta página

Pit Boss 30874, 10872 Manual Del Operador página 21

Publicidad

Idiomas disponibles

Idiomas disponibles

The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120 V, 60 Hz, 250 W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
FUEL INPUT
RATING:
1.12 KG/H
(2.48 LB/H)
GROUNDED
POWER CORD
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
110-120 V, 200 W
INDEX
K : BLACK
W : WHITE
R : RED
Y : YELLOW
P : PURPLE
O : ORANGE
G : GREEN
ELECTRICAL WIRE DIAGRAM
1. Locate and remove
the four screws of
access panel on the
side of hopper.
GROUND
W
P
R
AUGER MOTOR
& FEED SYSTEM
110-120 V, 60 Hz,
2 RPM MOTOR
2. Release bottom hopper
panel down and slide
back to unseat from tabs.
CONTROL BOARD
K
W
R
W
K
R
GRILL PROBE
Y
Y
DRAFT FAN
110-120 V, 60 Hz,
1 PHASE
21

Publicidad

loading