Descargar Imprimir esta página

Kübler Codix 131 Manual De Instrucciones página 10

Ocultar thumbs Ver también para Codix 131:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Main technical features:
Display:
LCD, 8 decades, height of the figures 8 mm.
Display range:
-9999999...99999999
with leading zeros suppression.
Overflow: In case of a display range overflow, the
counter starts again from 0, but without
removing the leading zeros and activating
all decimal points.
In case of a display range underflow, the
counter starts again from 0 and displays the
minus sign, without removing the leading
zeros and activating all decimal points.
Keys:
Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22,2+
x 45+
0,3 mm
Mounting depth:
approximately 48 mm
Weight:
approximately 50 g
Protection level:
IP65 on the front side
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1.5 mm
Input specification, pin assignment and adjustable operating modes (DC versions)
A control input (screw terminal 5) allows adjusting the operating mode.
Screw terminal
No. 1
Designation
INP A
Model
6.130.012.8x0
07 kHz
6.130.012.8x2
12 kHz
6.131.012.8x0
7 KHz
6.131.012.8x1
12 kHz
6.133.012.8x0
03 kHz
6.133.012.8x1
06 kHz
Table 2
Page 4 | ENG
0,6 mm
2
2 x 0.75 mm
2
AWG 26-14
No. 2
No. 3
INP B
Reset
NPN
30 Hz
NPN
PNP
NPN
NPN
7 kHz
NPN
12 kHz
PNP
PNP
3 kHz
NPN
NPN
6 kHz
PNP
PNP
EMC:
Interference emissions
Interference resistance
Device safety (for the AC models):
Design to:
EN 61010 Part 1
Protection Class:
Protection Class 2 (front side)
Only the front side is classified as accessible
!
for the operator.
Application area:
Pollution level 2
over-voltage Category II
Insulation:
Front:
double insulation,
Rear side: basic insulation, Signal inputs and und sen-
sor power supply: SELV
Power supply:
Non-replaceable lithium battery
(lifetime approximately, 8 years at 20°C)
Working temperature:
–10...+55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10...+60 °C
Storage temperature:
–20...+70°C
Altitude:
to 2000 m
Backlighting:
external electrical source
(24 V DC ±20 %, 50 mA)
SELV, CLASS II (Limited Power Source)
ext. fuse protection T0.08 A
No. 4
No. 5
Control inputs for operating
Reset
mode (Mode)
Enable
not active
=
adding
not active
=
Cnt.Dr Mode
not active
=
Quad Mode
EN 55011 Class B
EN 61000-6-2
No. 6
No. 7
BL
GND
contact with
GND =
subtracting
contact with
GND =
Up.Dn Mode
contact with
GND =
Quad2 Mode
No. 8
BL
+

Publicidad

loading

Este manual también es adecuado para:

Codix 130Codix 132Codix 133Codix 130hbCodix 130dc