Laydown Position Calibration – Z axis (LMH600 only)
Keep the instrument in its current position. Power OFF the instrument.
1.
Power ON the instrument while holding the (G) button down. You will know if Calibration
Mode is activated when the Battery and Anti-Drift LEDs flash alternately.
2.
The (H) and (I) button change the axis increments. The (H) button will produce a
positive (+) increment, and the (I) button will produce a negative(-) increment.
3.
The adjustments are automatically saved.
You must now repeat the peg test to insure you have made the correct calibration. A peg test can
be done in Calibration Mode.
MAINTENANCE AND CARE
Always clean the instrument after use. Use a soft, dry cloth to remove any dirt or moisture from the
instrument. Do not use benzene, paint thinner, or other solvents to clean the instrument. Store the
instrument in its case when not in use. Batteries should be removed before long-term storage.
ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing as waste. The machine, accessories and packaging
should be sorted for environmental-friendly recycling. Do not throw used batteries into waste, fire
or water but dispose of in an environmentally friendly manner according to the applicable
legal regulations.
Rechargeable Battery Pack: For maximum battery life, the battery pack must contain a full charge.
Properly charged, the battery pack will begin to perform optimally after five full charges
and discharges.