Descargar Imprimir esta página

JUMO flowTRANS MAG H20 Manual Breve página 58

Ocultar thumbs Ver también para flowTRANS MAG H20:

Publicidad

Idiomas disponibles

Idiomas disponibles

7 Modbus address tables
7.5
Process values
Measured values
Modbus PDU
Data type
address
dec
hex
6000
1770
float
6002
1772
float
a
r/-: Read access
Transfer of configuration
Modbus PDU
Data type
address
dec
hex
6450
1932
boolean
a
r/-: Read access
Totalizer
Modbus PDU
Data type
address
dec
hex
6750
1A5E
float
6752
1A60
float
a
r/-: Read access
Batch function
Modbus PDU
Data type
address
dec
hex
6800
1A90
boolean
6801
1A91
float
6803
1A93
boolean
6804
1A94
float
a
r/-: Read access
26
Number of
Ac-
a
Modbus
cess
registers
2
r/-
2
r/-
Number of
Ac-
a
Modbus
cess
registers
1
r/-
Number of
Ac-
a
Modbus
cess
registers
2
r/-
2
r/-
Number of
Ac-
a
Modbus
cess
registers
1
r/-
2
r/-
1
r/-
2
r/-
Data
Flow
Temperature
Data
Restart required after trans-
fer of configuration?
Data
Totalizer 1 volume quantity
absolute value
Totalizer 2 volume quantity
absolute value
Data
Alarm signal
Residual volume
Status
Filled volume
Encoding
Encoding
Encoding
Encoding
Active / inactive

Publicidad

loading