2 Adjustment of minimum level of the flame
Control handle
Tap
Sealing ring
• Do not dismantle the tap shafe: in the event of a malfunction, change the whole
tap.
• Before placing the burners back on the top place, make sure that the injector is
not blocked. carried out after gas conversion. (such as soap water or gas in the
event of a malfunction, change the whole tap.
• A full operational test and a test for possible leakages must be detector) Do not
dismantle the tap shafe:
• After completing conversion a qualified technician or installer has to mark "V"
on the right gas category to match with the setting in rating plate. Remove the
previous setting "V" mark.
1. Turn the taps down to minimum.
2. Remove the knob from the tap and place a
small bladed screwdriver in the centre of the
tap shaft.
3. The correct adjustment is obtained when the
flame has a length of about 3 - 4 mm.
• For butane / propane gas, the adjusting screw
must Make sure that the flame does not go
out by quickly turning from maximum flow to
minimum flow. If it does then remove the control
knob and make further adjustments to the gas
flow, testing it again once the adjustment has
been made.
4. Repeat this process for each one of the gas
taps.
EN
39