RECOMMENDED COMBINATIONS
Process
Type
Standard
TIG DC
PULSE
SPOT
Standard
MMA
PULSE
DC
0.3 - 3 mm
2.4 - 6 mm
4 - 8 mm
ELECTRODE SHARPENING
For optimal operation, it is recommended to use a sharpened electrode as follows:
SAVE AND LOAD WELDING SETTINGS
Saved settings: 10 in MMA mode and 10 in TIG DC mode.
The menu is accessed by pressing the
Saving a configuration
Once in programme mode, select IN and press the access button.
Slect a program from P1 to P10. Press the access button and the current setting is saved.
Load an existing setting
Once in program mode, select OUT and press the access button.
Slect a program from P1 to P10. Press the access button and the setting is loaded.
TRIGGER COMMAND CONNECTOR
DB
L
Wiring diagram according to the type of torch.
Torch with 2 triggers
TIG PRO 161 DC
HF
Lift
-
Current (A)
5 - 75
60 - 150
100 - 160
d
button.
4
L
2
3
torch
Torch type
Torch with 1 trigger
Electrode (mm)
Shroud (mm)
1
1.6
2.4
L = 3 x d for a low current.
L = d for a high current
L
4
3
5
2
DB
torch
6
1
NC
Wire description
Common/Earth
Switch trigger 1
Switch trigger 2
Argon flow rate
(L/min)
6.5
6 - 7
8
6 - 7
9.5
7 - 8
3
4
2
Electric diagram based on type of torch used.
Pin
2
4
3
EN
DB torch
L torch
25