The junction box should be
wired as shown.
Ground (Green
with Yellow Stripe)
Blue
Electrician to
provide suitable
strain relief.
Supply
Brown
9. Install the Plumbing
CAUTION: Risk of property damage. Ensure a watertight seal on the whirlpool drain.
Connect the drain to the trap according to the drain manufacturer's instructions.
NOTICE: An access panel will simplify future maintenance.
Install the faucet valving according to the faucet manufacturer's instructions. Do not install the
faucet trim until instructed. Open the hot and cold water supplies, and check the supply
connections for leakage.
Run water into the whirlpool, and check the drain connections for leakage.
If required, install the grip rails. Refer to the installation instructions packed with the grip rails.
10. Make Electrical Connections
NOTE: The product model number is printed on a label on the pump side of the whirlpool bath. This
label also identifies the electrical rating of the product. All whirlpools come equipped with a wiring
junction box and are designed to operate between 220 V and 240 V at either 50 Hz or 60 Hz.
WARNING: Risk of electrical shock. Make sure the power has been disconnected before
performing the following procedures. Refer to the "Important Information" section.
WARNING: Risk of electrical shock. To reduce the risk of electrical shock, connect the pump to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This
will provide additional protection against line-to-ground shock hazard. A 220-240 V, 20 A, 50/60 Hz
dedicated circuit is required.
The whirlpool bath control and system have been pre-wired at the factory. A licensed electrician
should make a routine service connection to the junction box.
Connect service to the junction box. The junction box contains blue, brown, and green with a yellow
stripe colored wires and a ground lug
Provide a separate equipment earthing conductor for the earth lug located inside the junction box.
Do not connect the earthing conductor to any current-carrying conductor. Follow local electrical
codes. Bond in accordance with national and local codes.
A wiring harness has been pre-wired at the factory, allowing communication between the keypad,
all features, and the control. No additional wiring is required, but ensure that all wires are securely
fastened.
NOTE: Your wiring harness included an antenna for the optional remote control. Do not alter or damage
this antenna during installation.
1022199-2-F
Bond in accordance with
national and local codes.
Wire
Connectors
From Control
60 Hz 50 Hz From Control
L1
L1
L2
N
Heater (models may
vary) T-style (shown)
or inline (not shown)
Wiring
Harness
Brown
Junction
Box
Blue
10
Heater Electrical Cord
Pump
Electrical
Cord
Control
Kohler Co.