Adam Equipment RAV Serie Manual De Usuario página 4

Ocultar thumbs Ver también para RAV Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1.
"ON". Press briefly to turn the scale on. A self-test will run on the display.
2.
"OFF". Press and hold for approx. 2 seconds to turn the scale off.
3.
"Tare". Press to subtract the weight of container currently on the scale (max.
tare weight = maximum capacity of the scale). When a tare value is set, an
indicator mark will show next to the 'Net' symbol on the front and rear display.
4.
"Zero". To reset the displayed weight back to zero (only operates when the
displayed weight is ≤ ± 2% of the max. capacity). When a zero value is set, an
indicator mark will show next to the 'Zero' symbol on the front and rear
display.
5.
"CE". Clear key: Press to clear the current unit price or other function values
from the display.
6.
"MC". No function on approved scales.
7.
"CH". Change: After the total price is calculated, press CH and enter the
amount paid by the customer and the scale will display the change to be
returned to the customer.
Example: The total price is $15 and customer pays with $20, press CH and enter 20.00.
The Unit Price window will display C 5.00 as the change for customer.
8.
"MR". No function on approved scales.
+
9.
"
". No function on approved scales.
10. "M+". No function on approved scales.
11. "QTY". Quantity key: After a unit price has been entered, press this key then
enter how many pieces and the total price will be calculated (up to 99 pieces).
12. "PLU". Price Look Up key - PLU: P01 to P40. To store a unit price into PLU key,
simply enter desired unit price and press the PLU key, then press selected PLU
recall key and the unit price will be stored into that designated key.
13. "00". Double Zero key. E.g. press "5" "00" to enter 5.00 as the unit price per
kg.
14. "P1/P2". Press to switch between primary (P1-P20) and secondary
(P21-P40) PLU value. The P1 or P2 indicator on the left of the LCD display
shows which group is selected.
15. "P01 / P21" etc. PLU recall keys. When a unit price has been stored into P01
to P40 keys, press the appropriate keys to recall stored unit price and it will be
displayed in the Unit Price window.
Example: To program PLU P01 as £130.75 per kg
Press CE to clear display.
Press P1/P2 until mark on the left of the LCD display shows P1 is selected
Press 1, 3, 0, 7, 5, PLU, P01 / P21 (Note: You must press PLU and the desired PLU
key quickly whilst 'PLU 00' is still showing on the lower display line).
16. "0, 1 ...9". Numeric keys - use to enter values.
17. The display backlight comes on automatically when a load is applied. It
remains on for as long as the load is applied, or switches off 10 seconds after
no load is detected.
NOTE: A double beep sound when pressing a key usually indicates an invalid
action, function not available, or an error.