Descargar Imprimir esta página

Titan IMPACT 1140 Manual De Mantenimiento página 13

Airless equipo de alta presión para pulverizar
Ocultar thumbs Ver también para IMPACT 1140:

Publicidad

Idiomas disponibles

Idiomas disponibles

IMPACT 1140
3.1
DIGI-TRAC™ CONTROL SYSTEM ERROR
MESSAGES (1140 / 1140I ONLY)
The following error message screens appear
i
whenever the Digi-Trac™ Control System detects a
problem with the sprayer. Once a problem occurs
and the error message appears, the sprayer will shut
down.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
CHECK TRANSDUCER SCREEN
The Check Transducer screen appears
when the transducer has become
disconnected or is defective. Take the
sprayer to a Titan authorized service
center for repair.
CHECK POTENTIOMETER SCREEN
The Check Potentiometer screen appears
when the potentiometer has become
disconnected or is defective. Take the
sprayer to a Titan authorized service
center for repair.
LOW VOLTAGE SCREEN
The Low Voltage screen appears when
the sprayer shuts down because of low
input voltage. Check the power supply
and correct the problem. Restart the
sprayer by following the "Painting"
procedure in the Operation section of this
manual.
HIGH MOTOR TEMPERATURE SCREEN
The High Motor Temperature screen
appears when the temperature of the
motor has risen too high. Take the
sprayer to a Titan authorized service
center for repair.
HIGH MECHANICAL LOAD
The High Mechanical Load screen appears
CHECK TRANSDUCER
when the sprayer shuts down because
of high current or when the sprayer goes
into current fold back mode. Take the
sprayer to a Titan authorized service
center for repair.
HIGH CONTROL TEMPERATURE
CHECK
POTENTIOMETER
Indicates the Digi-Trac is shut down due
to excessive heat. Take the sprayer to a
Titan authorized service center for repair.
CHECK MOTOR
Indicates the motor or motor hall affect
LOW VOLTAGE
sensors are defective. Take the sprayer
to a Titan authorized service center for
repair.
BAD HALL CYCLE POWER
Indicates the motor is shut down due to
connection problems between the motor
and controller. Take the sprayer to a Titan
authorized service center for repair.
HIGH MOTOR
TEMPERATURE
TROUBLESHOOTING
HIGH MECHANICAL
LOAD
HIGH CONTROL
TEMPERATURE
CHECK MOTOR
BAD HALL CYCLE
POWER
13

Publicidad

loading

Este manual también es adecuado para:

Impact 1140iImpact 1140ia24192942419291805-012