Installation and Connection

3.3.2 Emission and Immunity Levels

EMC Phenomenon
Emission:
Mains Terminal.
Disturbance Voltage.
Frequency Range: 150 kHz to 30 MHz).
Electromagnetic Radiation Disturbance"
Frequency Range: 30 MHz to 1000 MHz).
Immunity:
Electrostatic Discharge (ESD).
Fast Transient-Burst.
Conducted Radio-Frequency Common
Mode.
Surges.
Radio-Frequency Electromagnetic Field.
Definition of Standard IEC/EM 61800-3: "Adjustable Speed Electrical Power Drives
Systems"
Environments:
First Environment: environments that include domestic installations, as well as establishments
directly connected without intermediate transformer to a low-voltage power supply network
which supplies buildings used for domestic purposes.
Second Environment: includes all establishments other than those directly connected to a low-
voltage power supply network that supplies buildings used for domestic purposes.
Categories:
Category C1: inverters with a voltage rating less than 1000 V and intended for use in the First
Environment.
Category C2: inverters with a voltage rating less than 1000 V intended for use in the First
Environment, not provided with a plug connector or movable installations. They must be installed
and commissioned by a professional.
NOTE!
A professional is a person or organization familiar with the installation and/or
commissioning of inverters, including their EMC aspects.
Category C3: inverters with a voltage rating less than 1000 V and intended for use in the
Second Environment only (not designed for use in the First Environment).
24 | CFW500
CALL NOW 800-985-6929
http://www.automatedpt.com
Table 3.4: Emission and immunity levels
Basic
Standard
IEC/EN 61800-3
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-6
IEC 61000-4-5
IEC 61000-4-3
http://www.automatedpt.com
Email: charles@automatedpt.com
Level
It depends on the inverter model on the
length of the motor cable. Refer to
B.3 on page
145.
4 kV for contact discharge and 8 kV for air
discharge 8 kV.
2 kV / 5 kHz (coupling capacitor) input cables.
1 kV / 5 kHz control cables and remote HMI
cables.
2 kV / 5 kHz (coupling capacitor) motor
cables.
0.15 to 80 MHz; 10 V; 80 % AM (1 kHz).
Motor, control and HMI cables.
1.2/50 μs, 8/20 μs.
1 kV line-to-line coupling.
2 kV line-to-ground coupling.
80 to 1000 MHz.
10 V/m.
80 % AM (1 kHz).