Descargar Imprimir esta página

hillvert HT-HECTOR-6600 Manual De Instrucciones página 56

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 197
Tension hydraulic pump belt
1) Remove belt guard.
2) Access the two nuts on the under side of the chassis and slacken using a 19 mm socket
spanner.
3) Adjust the M8 bolt on the outside plate until the desired tension is achieved. For instructions
on checking belt tension & correct belt tension values, please refer to the V-Belt Tensioning
Data Table.
4) Retighten the two nuts to (88 Nm) 65 Ibs/ft.
5) Refit belt guard.
Change hydraulic oil and filter
WARNING
Use plastic gloves to keep oil off skin and dispose of the used oil and filter in an
ecologically sound way. The oil and filter should be changed once a year or at any
time it becomes contaminated. Before starting check that the chipper is standing level
and brush away loose chips.
1) Remove the black screw cap from the top of the filter housing.
2) Partially remove filter element from inner cup. Leave filter to drain for 15 minutes.
3) Remove filter element from cup when clear of hydraulic oil.
4) Remove drain plug and drain oil into a suitable container.

Publicidad

loading