HEAT PROTECTOR TABLE
Mod.
Pump Code
1
newBCC 300M
2
newBCC 300T
3
newBCC 400T
4
newBCC 550T
• For single-phase pumps 230V (newBCC300M) use connecting cable type H07
RN-F3 of 2,5 mm
F5 of 1,5 mm
electrical section for the newBCC400T and newBCC550T
• Before connecting the motor, check the necessary fuse type.
• Check the correct arrangement and connection to the earth wire in the equipment
installation.
• It is very important to keep to the installation and electrical connection conditions.
Should they not be heeded, the pump manufacturer does not accept any
responsibility and considers the guarantee void.
• The motors are subject to EEC regulations with IP-55 protection.
• Special installation regulations may exist.
• Incorrect mains connection could result in death.
CV
KW
3
2,2
3
2,2
4
2,9
5,5
4
electrical section. For three-phase pumps, use cable H07 RN-
2
section for the newBCC300T and cable H07 RN-F5 of 2,5 mm
2
V.
Intensity relay regulation (A)
230
230/400
230/400
230/400
23
12
7 / 4
12,6 / 7,3
14,9 / 8,6
2