The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396. The
installation must be done observing the norms in force particularly concerning room ventilation and discharging gas
emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
•
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
•
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is effected; above all, the appliance must be installed in
a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas emissions
which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power installed.
During installation it is necessary to observe a maximum distance between the front edge of the supporting cabinet and
the appliance. (See drawing at item "emptying the water tub")
DIMENSIONS
NOMINAL HEAT OUTPUT (KW)
GAS CONNECTION ISO R7
WATER FILLING
WATER DRAINAGE
Ensure that the air outlets in the place of work are sufficient to guarantee the necessary air exchange, as stated in
paragraph 4.3 of the UNI-CIG. norm 8723.
We remind you that appliances installed in buildings for public use must meet the following requirements:
In Italy:
1) Installation regulations
Installation and maintenance of the appliance must be carried out following the correct procedures and written
regulations in use, in particular:
•
safety norms against fire and panic in public buildings
a)
general instructions
-
For all appliances:
the connection, installing the system and appliances, ventilation and fumes extraction system must be done in
accordance with the manufacturer's instructions by professionally specialized personnel in compliance with the
UNI-CIG norm 8723. The electrical part must comply with the E.I.C. norms in force; furthermore, the current
rules established by the Fire Brigade must be observed.
In Switzerland:
The appliance must be installed in accordance with the safety norms in force.
Installation, conversion and repairs of appliances for professional use, as also the withdrawal for breakdowns and gas
supply connections may be carried out only on the base of a maintenance contract drawn up with an authorized sales
agent and observing the technical norms.
The appliance may be installed as a single element or in series with other appliances of our production. It is necessary to
observe a minimum distance of 10 cm from the appliance to prevent contact with walls of inflammable material;
adequate measures must also be taken to ensure thermal insulation of inflammable parts, such as the installation of a
protection against radiation; particular attention must be paid in installing the appliances adequately and safely. The feet
are adjustable in height so that differences in level can be avoided.
GB
DECLARATION OF COMPLIANCE
INSTALLING THE APPLIANCE
GAS TECHNICAL DATA TABLE
MODEL
CHECKING FOR CORRECT VENTILATION
IE
CP-74G
CP-76G
40x70x90
60x70x90
9,5
13,95
R 1/2GM
R 1/2GM
R 1/2GM
R 1/2GM
R 1GF
R 1GF
27
CP-78G
80x70x90
19
R 1/2GM
R 1/2GM
R 1GF