In both cases the "
directed in the direction of power circulation from the
source to the load. In which case:
- the "+" sign corresponds to power consumed by the
load.
- the "-" sign corresponds to power supplied by the load.
Specific reference conditions
PF = 1; I ≥ 2 A; U ≥ 10 V
Active power measurement characteristics
Display range
Measuring range (2)
Accuracy (3)
Resolution
Reactive power measurement characteristics
Display range
Measuring range (2)
Accuracy (3)
Resolution
Apparent power measurement characteristics
Display range
Measuring range (2)
Accuracy (3)
Resolution
1) the scale is limited to 240 kW (kvar, kVA) in one-phase
(
(600 V x 400 A) and 399.9kW (kvar kVA) in 3 phases system.
Above this value, the display indicates +OL or -OL depending
on the sign of the power.
(2) if the power value is < 5 W or if the voltage or current
values are respectively < 0.15 V or < 0.15 A, 0 is displayed.
(3) The measurement accuracy is affected by an instability
linked to current measurement of approximately 0.1 A.
Example: for a power measurement performed at 10 A, the
instability of the measurement will be 0.1 A/10 A, or 1%.
MIN/ MAX Mode:
- Accuracy: same as previous table +0.3% L
- Capture time: 100 ms typ. (every 400 ms)
3.9 Power factor calculation (PF)
With the clamp configured in power measurement (switch
on position W) and correctly connected (see § 3.8), perform
a short press on the yellow key: the power factor is displayed.
The power factor is, by definition, an unsigned quantity,
however, a sign is displayed showing whether the charge is
inductive ("+" sign) or capacitive ("-" sign). This sign is
significant only in the case of slightly distorted signals (i.e. 3
switches to zero over 1 period).
" arrow on the jaws, must be
4000 W
40 kW
5 to
4,00 kW to
3999 W
39,99 kW
2% L + 1 pt
1 W
10 W
4000 var
40 kvar
5 to
4,00 kvar to
3999 var
39,99 kvar
2% L + 1 pt
1 var
10 var
4000 VA
40 kVA
5 to
4,00 kVA to
3999 VA
39,99 kVA
2% L + 1 pt
1 VA
10 VA
36
400 kW
40,0 kW to
-399,9kw (1)
240,0 kW
100 W
400 kvar
40,0 kvar to
240,0 kvar ( 1)
100 var
400 kVA
40,0 kVA to
240,0 kVA (1)
100 VA