Hella Gutmann
Continuous operation
Weight
Dimensions
IP degree of protection
Bandwidth
Sampling rate
Memory depth
Amplitude resolution
Overload protection
Measuring channels
Measured variables
Measuring accuracy
Interfaces
Ranges
Voltage
Current
MT-HV
ja
approx. 270 g
43 x 110 x 136 mm (H x W x D)
IP20
max. 10 MHz
64 MSa/s
64 kB
14 bit
max. 200 V
2 (galvanically isolated)
• Voltage
• Current (external clamp meter)
• Resistance
• Pressure (external LPD kit)
+/- 2.5 %
• 4x safety socket 4 mm (2 per measuring channel)
• 1x ST3 (12-pin)
• 1x module interface (USB)
ST3 connections
• 6x communication
• 1x voltage inlet 10-15 V
• 1x voltage outlet +17 V
• 2x scope (+/-)
• 1x hardware detection (coding)
• 1x ground
• Range: 10 positions, 0,01-20 V/Div
• Measurable Voltage: max. 200 V
• Blue clamp (CP 700):
– Measuring range: ± 700 A
– Current load: max. 25 mA
• Green clamp (CP 40):
– Measurable current: -10 to 40 A
– Current load: max. 25 mA
General information | 8.