Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the PHS-200 starts running. During the Reset, the motors are
trimmed and the device is ready for use afterwards.
Stand Alone operation
In the Stand Alone mode, the PHS-200 can be used without controller.
Disconnect the PHS-200 from the controller and call the internal program.
1. Press [ENTER] for 3 seconds to enter the main menu "MODE" (display flashing)
2. Press [ENTER] and select "RUN" by pressing [UP] button.
3. Press [ENTER] and select "AUTO" by pressing [UP] button.
4. Press [ENTER] and select "ALONE" by pressing [UP] button.
5. Press [ENTER] to confirm, the display shows "AU-A".
6. Press [EXIT/DN] in order to return to the main menu.
Please refer to the instructions under Control Board, Main functions, menus Run and Edit.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. The individual channels and their features are listed under DMX-protocol.
Addressing
The Control Board allows you to assign the DMX starting address, which is defined as the first channel from
which the PHS-200 will respond to the controller.
Please, be sure that you don't have any overlapping channels in order to control each PHS-200 correctly and
independently from any other fixture on the DMX-chain.
If several PHS-200 are addressed similarly, they will work synchronically.
Press the Up/Down-buttons for setting the desired starting address. Now you can start operating the PHS-
200 via your lighting controller.
International
L
N
38/95
00025926.DOC, Version 1.5