Fan motor sounds
abnormal.
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and damages to the induction hob.
9. Installation
9.1 Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select heat-resistant and insulated
work surface material (Wood and similar fibrous or hygroscopic material shall not be used as work surface
material unless impregnated) to avoid the electrical shock and larger deformation caused by the heat
radiation from the hotplate. As shown below:
Note: The safety distance between the sides of the hob and the inner surfaces of the worktop
should be at least 3mm.
L(mm)
W(mm)
H(mm)
62
590
520
Under any circumstances, make sure the Induction cooker hob is well ventilated and the air inlet and
outlet are not blocked. Ensure the induction cooker hob is in good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above the hotplate should be at
least 760 mm.
The fan motor is
damaged.
D(mm)
A(mm)
B(mm)
58
560+4
490+4
+1
21
Replace the fan.
X(mm)
F(mm)
50 min.
3 min.
+1
V.1