Descargar Imprimir esta página

golmar Stadio Plus T500SE ML Manual De Instalación página 55

Ocultar thumbs Ver también para Stadio Plus T500SE ML:

Publicidad

Idiomas disponibles

Idiomas disponibles

DOOR PANEL INSTALLATION
P
ush buttons limit.
The maximum number of push buttons to be connected depends on the number of installed
EL516SE encoders, as it is shown on the following chart:
Without EL516SE circuit:
8
With 1 EL516SE circuit:
7 + 15 = 22
With 2 EL516SE circuits:
6 + 15 + 15 = 36
With 3 EL516SE circuits:
5 + 15 + 15 +15 = 50
With 4 EL516SE circuits:
4 + 15 + 15 + 15 +15 = 64
With 5 EL516SE circuits:
3 + 15 + 15 + 15 +15 + 15 = 78
With 6 EL516SE circuits:
2 + 15 + 15 + 15 +15 + 15 + 15 = 92
With 7 EL516SE circuits:
1 + 15 + 15 + 15 +15 + 15 + 15 + 15 = 106
With 8 EL516SE circuits:
0 + 15 + 15 + 15 +15 + 15 + 15 + 15 +15 = 120
In case to combine these door panels with coded door panels or porter's exchange it will be
necessary to know these codes for a properly system configuration.
The codes shown on the first column (shadowed) correspond with the push buttons directly
connected to the corresponding terminal on the CN6 terminal connector of the EL500SE
circuit, or with the terminal 1 of its corresponding EL516SE encoder.
1
2
3
4
5
P1
1
2
3
4
5
P2
16
17
18
19
20
P3
31
32
33
34
35
P4
46
47
48
49
50
P5
61
62
63
64
65
P6
76
77
78
79
80
P7
91
92
93
94
95
P8
106
107
108
109
110
111
P
ush buttons digital code.
EL516SE terminals
6
7
8
9
10
11
12
13
14
15
6
7
8
9
10
11
12
13
14
15
21
22
23
24
25
26
27
28
29
30
36
37
38
39
40
41
42
43
44
45
51
52
53
54
55
56
57
58
59
60
66
67
68
69
70
71
72
73
74
75
81
82
83
84
85
86
87
88
89
90
96
97
98
99
100
101
102
103
104
105
112
113
114
115
116
117
118
119
120
107
108
D
escription of the SW1 configuration dip-switch of
the EL500SE microprocessor module.
The SW1 configuration dip-switch is located at the right side of
the circuit. It is accessed by opening the terminal connection
block protection cover.
Factory default
DOOR PANEL INSTALLATION
Placed to OFF if the EL500SE microprocessor module is configured as EL500
operating mode
.
Set to ON if the EL500SE microprocessor module is configured as EL501
operating mode
(general door panel).
Selects the d
oor opening time,
done from the
terminal), see page 138.
Placed to ON: door opening timed at 3 seconds.
Set to OFF: door opening timed at 15 seconds.
Selects the type of cable to be used for the video signal.
Placed to OFF: coaxial cable RG-59 o RG-11.
Set to ON: twisted pair.
Selects if the door panel has telecamera or not. In case of door panels without
telecamera (EL540 sound module) set to ON.
Plus system, loads the installation with a communications resistor Plus. For a
proper system operation, placed to ON only in the closest door panel to the
backbone installation or in the general door panel (if exists), set the rest to
OFF.
Uno System,
loads the installation with a communications resistor Uno. For a
proper system operation, set to ON only in the closest door panel to the
backbone installation, placed the rest to OFF.
With digital repeater RD Plus/UnoSE:
In the backbone installation or after the inner door panel in systems with
general door panels, placed the door panel/s to OFF.
Set to ON so that the volume tone emitted by the door panel:
(call reception, busy system and lock release) are HIGH, or placed to OFF if a
LOW volume tone is desired.
Placed to ON,
the calls made on the door panel will be transferred to the
porter's exchange (if exists).Set to OFF , the call is received in the apartment.
In general door panels systems with porter's exchange, this function is only
applicable to the general door panels not to the inner door panel/s.
external push button
('AP'

Publicidad

loading