DOOR PANEL INSTALLATION
D
escription of the SW2 configuration dip-switch of
the EL500SE microprocessor module.
The SW2 configuration dip-switch is located in the center
of the circuit. It is accessed by opening the terminal
connection block protection cover.
Allows to activate the autoswitch-on function (audio-video communication
without previous call) at the door panel that has this switch to ON position.
In systems with several door panels activate this function only in one of
them; in systems with general door panel this function can be activated in
one door panel of each inner backbone (building).
Set to ON for monitor or telephones programming. Once the programming
progress is finished return the switch to OFF position. The programming
process is described on pages 120 (monitors) and 124 (telephones).
In general door panel (EL501 mode), set to ON for general door panel
push buttons programming or backbone (building) monitor/telephones.
The programming process is described on pages 110 to 112. Once the
programming progress is finished return the switch to OFF position.
Set to OFF in case of a master door panel. Each system must have only one
master door panel; the rest must be slaves (ON).
In systems with general door panel, set as master one door panel of each
inner backbone (building) and the general door panel as slave. Of this
way, the user will be able to distinguish since door panel are calling him.
Switches number 4 to 10 set the building code. In backbones with several
door panels, set the same code in all the panels; in systems with general
door panel, set different codes for each inner backbone (building). Set a
code between 1 and 120 for inner backbones (up to 127 with coded
panel) and a code 0 (
code use binary coding as shown on the next paragraph.
Factory default
The switches set to OFF have null value. The values of the switches
set to ON are shown in the enclosed chart.
The backbone code will be calculated as the sum result of the
switches values set to ON.
Switch number:
4
5
6
7
8
ON value:
64
32
16
8
4
Factory default
) for general door panel/s. To set the
B
inary coding of the SW2 configuration dip switch
of the EL500SE microprocessor module.
9
10
2
1
Example: 64+0+16+0+4+2+1=87
109
110
G
eneral door panel (programming modes).
Configure the
microprocessor module
The general door panel permits the following programming modes:
O Programming the push button (by call of monitor).
O Programming the push button (with a backbone code).
O Programming the push button (with a monitor/telephone code).
O Programming the monitor/telephone.
P
rogramming the push buttons of the general door panel.
Programming the push button (by call of monitor/telephone):
This programming mode allows to assign a monitor / telephone (programmed) to the push button of
the general door panel that it wishes to call.
Before the monitors/telephones of the inner door panel/s must be programmed, see page 120
(monitors) and 124 (telephones).
IMPORTANT: Before programming the general door panel push buttons, switch off the porter's
exchange (if exists).
GENERAL DOOR PANEL INSTALLATION
of the general door panel in EL501 mode, (see page 108).
Locate the SW2 configuration dip switch of the general door
panel to program, placed in the center of the EL500SE circuit.
With the switches 1 and 3 to OFF , set the switch 2 to ON: to
show that the system is ready for programming, the general
door panel will reproduce a tone.
Pick up the monitor/telephone handset of the apartment to
program and press the door release push button until to
establish communication of audio with the general door
panel.
T-740Plus
Press the general door panel push button that will call to this
monitor or telephone. At this moment the general door
panel will reproduce a tone. To finish the push button
programmation, replace the monitor/telephone handset;
to show that the push button has been succesfully
programmed, the general door panel will reproduce a tone.
Make a call to check that the push button has been succesfully programmed.
Repeat these steps to program the rest of push buttons.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the general door panel will reproduce a tone to advise
that the system is still into programming mode.