Electric Start
1. Make sure all appliances are
disconnected from the generator.
2. Turn the choke lever to the
"START" position. (When the
engine is warm or temperature is
high, start engine with the choke
lever in the "RUN" position).
3. Set the engine switch to the
middle "ON" position. Press and
hold the toggle to the "START"
position to engage the starter.
Release, set switch to
the "ON" position when engine is
running.
To prolong the life of starter components, DO NOT hold switch in
"START" position for more than 15 seconds, and pause for at least 1
minute between starting attempts.
Do not connect appliances with defective power cords and/or
plugs.
• Be sure appliances are not connected to generator when
starting up. Starting the generator with an appliance connected
could result in damage to the generator and/or appliances and
personal injury.
• DO NOT turn the starting motor over 5 seconds continuously.
If the engine fails to start, return the engine switch to the "ON"
position and wait about 10 seconds and then start again.
• DO NOT press the engine switch to the "START" position when
the engine is running to prevent damage of starting motor.
• Do not overload the generator.
• Do not overload individual panel receptacles. These outlets
are protected against overload with push-to-reset-type circuit
breakers. If amperage rating of any circuit breaker is exceeded,
that breaker opens and the electrical output to that receptacle
is lost.