Since the fuel (gasoline) will deteriorate with time, replace fuel
(gasoline) with fresh fuel periodically; every three months or
add a fuel stabilizer.
Spark Arrester
The spark arrester must be cleaned regularly to keep it
functioning as designed. A clogged spark arrester:
• Prevents the flow of exhaust gas
• Reduces engine output
• Increases fuel consumption
spark arrester.
Clean The Spark Arrester Screen
1.
down completely before servicing spark arrestor (located on
2. Remove the clamp and spark arrestor screen.
3. Clean the spark arrestor screen with a small wire brush.
4. Replace the spark arrestor if it is damaged.
5. Installation of the spark arrestor screen is the reverse of the
removal.
Valve Clearance
After the first 50 hours of operation, check the valve clearance in
the engine and adjust if necessary.
Important: If feeling uncomfortable about doing this procedure or
the proper tools are not available, please take the generator to
the nearest service center to have the valve clearance adjusted.
This is a very important step to ensure longest life for the engine.
Transporting
When transporting the generator, make sure that the fuel (gasoline)
is drained from the tank.