Operation
Setting the cutting angle
♦
Undo the clamping screws
key
and pull the footplate
♦
Adjust the cutting angle to 0°/15°/30°/45°
with the aid of the markings on the footplate
Push the footplate
locking pin engages in the toothing
♦
Retighten the clamping screws
key
.
NOTE
►
When using a cutting angle of 15°/30°/45°,
the pivoting blade guard
must be detached beforehand!
Setting the stroke rate
♦
Use the stroke rate adjusting wheel
required stroke rate.
Adjusting the pendulum stroke
♦
You can use the pendulum stroke switch
adjust the pendular movement of the saw blade
. You can achieve fine, clean-cut edges with-
out pendular movement (setting "0"). Deactivate
pendular movement when working on thin
workpieces. You can achieve an increasingly
fast work rate if the pendulum stroke is activated
(settings 1–3).
Switching ON/OFF
Switching the appliance on:
Press the ON/OFF switch
Switching the appliance off:
Release the ON/OFF switch
Switching to continuous operation:
Press the ON/OFF switch
position with the ON/OFF switch lock button
Switching off continuous operation:
Press the ON/OFF switch
PSTD 800 B2
with the hex
to the rear.
to the front so that the
.
with the Hex
and splinter guard
to set the
to
.
.
and lock it in this
and release it again.
Switching the laser/working light
ON/OFF
ON/OFF switch:
Press the ON/OFF switch
required function is active.
LASER and WORKING LIGHT → WORKING
.
LIGHT → LASER → SWITCH OFF
Sawdust blowing function
Switching the sawdust blowing function on:
♦
Slide the sawdust blower function switch
the position
Supporting the extraction function:
♦
Slide the sawdust blower function switch
the position "0".
Maintenance and cleaning
WARNING! RISK OF INJURY! Switch
the appliance off and remove the
power plug before starting any work
on the appliance.
■
The appliance must always be kept clean, dry
and free from oil or grease.
■
Use a soft, dry cloth to clean the housing.
WARNING!
■
If the supply cord of this power tool is dam-
aged, it must be replaced by a specially
prepared cord available through the service
organization.
■
Replace the saw blade
are too blunt for adequate sawing.
■
Clean the appliance after completing your
sawing work.
■
Remove any dirt (e.g. sawdust). If necessary,
clean the saw blade mount with a brush or
compressed air.
.
for the until the
.
as soon as its teeth
GB │ MT
│
in
in
41
■