Installation
Only an authorised installation engineer may carry out the installation.
The battery charger should be installed indoors in a space with a vapour barrier.
Locate the battery charger so that there is free circulation of air through the battery
charger's ventilating openings.
There are different models of the battery charger for placing on floors, or for wall
mounting. For wall mounting, the battery charger is screwed directly onto the wall
as per illustration.
The battery charger is produced in different mains voltage variations. Check that
the power supply at the site of the installation complies with the rate voltage
according to the information on the battery charger's rating plate.
The recommended mains fuse is specified on the battery charger's rating plate. Use
delay action fuses.
The battery charger is connected to the mains voltage via a cable with a plug to an
earthed wall socket.
Connect the battery charger as per illustration. Carefully check the marking on the
battery.
When connecting up connection cables to the wall model, the cables are screwed
securely into the connection blocks. After that, the cable stress-reliever is
tensioned.
When installing wiring in the floor model, the left-hand end plate can be removed
to facilitate installation. The end plates are secured with two screws at the bottom
and one or two screws at the top.
The red cable is connected to the battery's positive pole and the black or blue cable
is connected to the battery's negative pole.