5. If the cable being mapped is terminated in T568A, T568B, or Straight-
Through wiring, the Probe's Wire Map Indicators will illuminate 1 through 8,
in the order of contact pin termination, in unison with the Toner's Wire Map
in the order of contact pin termination, in unison with the Toner's Wire Map
Indicators
T18 T18
illuminating all effected wires' LEDs on both the toner and probe during the
detection sequence. For an open circuit, the wire's LEDs on both the toner and
probe will not be illuminated during the detection sequence.
6. If the cable being tested is shielded, the Shield Indicator on both the Toner
and Probe will illuminate at the end of each sequence.
7. The test will be repeated until one or both ends of the cable is/are
disconnected, or until the Toner's mode is cycled out of Mapping mode.
NOTE: The Digital Probe-Pro cannot ID digital/analog tone signals while in
mapping mode.
BATTERY REPLACEMENT
When the Low Battery Indicator
replaced.
1. Turn off instrument(s) before attempting to replace batteries.
2. Loosen screw
3. Remove and properly dispose of four 1.5V AAA batteries.
4. Install new batteries (note proper polarity).
5. Replace battery cover and fasten securely with screw.
To avoid risk of electric shock, do not operate while battery door
is removed.
OPERATING INSTRUCTIONS
. A short circuit between wires is indicated by simultaneously
MAINTENANCE
, on battery cover
T17 T17
blinks, the batteries must be
T11 T11
.
T16 T16
T19 T19
9