4 | Assembly / Mounting
Check the LED light before installation to ensure it is complete and shows no signs of damage. Do not use the light or
accessories if they are damaged, as there is a risk of injury.
The LED light comes fully assembled. The light is mounting at the screw-on base with four screws M6 (in delivery
scope). As option there are this mounting accessories:
Permanent Holding Magnet CENALED screw-on base
Table clamp CENALED screw-on base
Wall angle bracket CENALED screw-on base
5 | Connection
The direct current LED light has a sensor cable of three meters, PVC oil resistent, and two open cable ends for a direct
connection to a machine control for example.
cable strand, brown
cable strand, black
For further connection options, like cables, plugs or materials you can find in the accessories of LED2WORK.
6 | Maintenance and Care
The LED light is maintenance-free. Do not make any alterations to the light (except according to the mounting information
contained in this manual).
The LED light sources mounted in the light are connected to the luminaire housing in a special way (thermal coupling)
and may react sensitively to electrostatic discharges (ESD). Improper replacement of the illuminant or other compo-
nents may impair the tightness of the light. That is the reason why repairs may only be carried out by the manufactu-
rer or by persons authorised and qualified by the manufacturer.
Turn off the light before cleaning and let it cool down completely. Clean the outside of the luminaire with a soft, dry and
clean cloth. To remove excess dirt, moisten the cloth with water. Never use aggressive cleaning agents, as these may
cause discolouration of the housing.
When mounting the light, make sure that the light is fastened securely and stably. If the
light falls down, its weight poses a risk of injury!
+24V DC
GND
To turn on the light, activate the push button on top the head of the luminaire. Hold on
the push button for setting of the light intensity. Another pushing of the button turns the
light off.
Do not open the luminaire!
No liability is assumed for damages resulting from the use of unsuitable cleaning agents.
Product no.
220500-01
220500-02
220500-03