6. Wiring diagram
See chapter 14, Functions of dip switch and jumper wire, for dip switch settings.
Specifications are subject to change without notice.
PAA-A18, 24, 30, 36, 42AA1/BA1/CA1 and all-
30
Symbol Explanation
P.B.
Power Supply Board
I.D.U.
Indoor Unit Control Board
R.B.
Relay Board
F01
Fuse, AC250V 10A
F02
Fuse, AC250V 6.3A
Return Air Thermistor
CNH05
CN105
Interface Connector
SW01
Switch (for Model Selection)
SW02
Switch (for Capacity Selection)
SW05
Switch (for Mode Selection)
CNF
Humidifier Input (required)
CN25
Humidifier Output
TH2 Pipe Temp. thermistor/Liquid
CN44
TH5 Cond./Evap Temp
TB-A
Terminal Block - A
TB-B
Terminal Block - B
TB-C
Terminal Block - C
CN4F
Float Switch
CN2A
0-10v Fan Control Input
CN24-1
Backup Heat (1st stage)
CN24-2
Backup Heat (2nd stage)
CNER
ERV/Damper Input (optional)
CN2C
ERV/Damper Output
ME system status signal
CN2L
CN32
ON/OFF Lockout Input
CN51
Error Status Output
G/Y1
Fan
W/W1
First Stage Furnace
W2
Secondary Stage Furnace
Y/Y2
High Speed Fan
R
24VAC Power From Furnace
C
24VAC Return To Furnace
© 2022 Mitsubishi Electric US, Inc.