Descargar Imprimir esta página

Beko BHCA66641BBBHS Manual De Instalación página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
1- Installation with flue - the
aspirated air is transferred to
the outdoor through a flue;
Installation dimensions and details
(Figure 3a-3b-4a-4b)
• The dimensions for the installation with
double flue are shown in Figure 3b.
• If the installation will be carried out as
a double-chimney, the length from the
required clearance distance above the hob
to your furniture shall be in the range of
910-1138 mm. (Figure 4b)
• If the installation will be carried out as a
single chimney, the length from the required
clearance distance above the hob to your
furniture shall be 748 mm. (Figure 3a-4a)
For a single flue installation, use the upper
flue with a ventilation hole.
Installation of product fixing parts
(Figure 5-6-7a-7b)
• Centre your hob and draw a vertical axis
line on the wall.
• Draw a horizontal reference line by
measuring a 650 mm distance from the
upper point of your hob. (Figure 5)
• Centre the supplied template to the
reference point drawn and stick it on the
wall and mark the holes in the template
with a pencil. (Figure 6)
• From the top of your furniture or ceiling,
mark the holes for the flue fixing parts as
per the dimensions shown in figure 6.
• Fix the hood fixing part and flue fixing parts
to the wall as indicated in figures 7a and
7b. Single-flue use is shown in figure 7a,
and double-flue use in figure 7b. (Part A is
intended for the installation with a carbon
filter)
Hanging, aligning and fixing the hood
(Figures 8-9-10-11)
• Hang your hood on the hood fixing part
that you have fixed to the wall. (Figure 8)
• Align your hob in a central position by
sliding the hood to the right and the left
direction on the fixing part. (Figure 9)
• Open the glass cover of the hood and take
out the aluminium filter as shown in the
figure 10.
• Fix your hood on the hood fixing part with
the glass cover open as shown in the figure
11.
• Close the hood glass cover after installing
the aluminium filter.
Installing flue outlet pipes (Figure
12a)
• As shown in Figure 12a, place the cover,
which prevents the reversed air flow, on the
10
chimney outlet.
• If the diameter of your flue outlet pipe is 150
mm, mount the flue outlet pipe on the cover.
• If the diameter of your flue outlet pipe is 120
mm, mount the flue outlet pipe after placing
the flue connection adapter on the cover.
• Insulate the joints appropriately.
Fixing the chimney sheets (Figures
13-14a-14b)
• Adhere the tape supplied with the
product around the joint of the plastic part
preventing reverse air flow and the hood
flue outlet (Figure 13).
• If you install the appliance with a single
flue extension, as shown in the figure 14a,
complete the installation by fixing the flue
extension, which has 4 screw holes, with
4 screws through the lower hole circles
available on the hood.
• If you install the appliance with a double
flue extension, as shown in the figure 14b,
fix the flue extension, which has 4 screw
holes, firstly, with 4 screws in a way that it
will be placed on the upper part. After that,
fit the flue extension, which has 2 screw
holes, on the fixed upper flue and complete
the installation by fixing it with 2 screws
through lower hole circles.
2- Installation with a carbon
filter where aspirated air will
be transferred to the indoor
by passing through a carbon
filter
• In the carbon filter installation, the air
sucked from the environment passes
through the aluminium filter and is purified
from odours. After passing through the
carbon filters and the air diverter, it is
supplied back to the environment through
the ventilation grilles on the side surface of
the flue. Flue outlet pipes are not used in
carbon filter installation.
• For installation, Figure 1-2 explanations are
applicable for the installation with flue.
Installation dimensions and details
(Figure 3-4)
• The dimensions for the installation with
double flue are shown in Figure 3b. For
the carbon filter installation, the 2 pieces
of A parts to which the air deflector will
be attached must be secured in the
dimensions shown in the figure 3d.
• If the installation will be carried out as
a double-chimney, the length from the
required clearance distance above the hob
to your furniture shall be in the range of
910-1138 mm. (Figure 4b)
• If the installation will be carried out as a
single chimney, the length from the required

Publicidad

loading